True metrix error codes e 0 - Advanced Features. No coding; As Fast as 4 Seconds; Tiny 0.5 microliter sample size; Alternate site testing; Store 500 results with time/date; 7,14, and 30-day ...

 
If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t.. Article_52605885 b637 53f9 ad63 64f7af3901a8

The TRUE METRIX Self-Monitoring Blood Glucose System is intended for self-testing outside the body (in vitro diagnostic use). To assure you are getting accurate and reliable results, you can perform a Control Test (Refer to Owner’s Booklet). HP Printer Driver Support for Linux OS. Linux operating systems are developed and supported by the open source community. To find driver support for the Linux operating system, HP recommends the HP Linux Imaging and Printing website HP Linux Imaging and Printing . Note: The HP Linux Imaging and Printing website is not hosted by HP …Blood glucose test result is above 600 mg/dL; blood ketone test result is above 8.0 mmol/L. Wash and dry your hands or test site and repeat the test using a new test strip. If your result still flashes HI, contact your health coach immediately.Mar 20, 2023 · TRUE METRIX test strips 50 count box. Test strips require only a tiny 0.5 µL (microliter) blood sample. Detects sample environment, sample size, and control solution. Analyzes environmental and physiological factors. Corrects hematocrit/temperature. For use with TRUE METRIX meters. For the most accurate results using TRUE METRIX: • Read all product instructions for use before testing. • Use of TRUE METRIX in a manner not specified in this Owner’s Booklet is not recommended and may affect ability to determine true blood glucose levels. Page 6 Control Solution are available for Control Tests.TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) System Specifications 4 System Specifications Meter Specifications Result Range: …The True Metrix meter also has features such as a ketone reminder, control detection, and audible fill detection to keep users on track. Strip Release Button Handling a strip after testing can have an impact on its accuracy. The True Metrix blood glucose meter has a handy strip release button.Apr 4, 2023 · Potential error codes that may occur while testing blood sugar. Specific Error Codes E 0 1:10 E 1 1:32 E 2 1:53 E 3 2:18 E 4 2:40 E 5 2:49 E 6 3:11 E 9 3:32 Other error... TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) System Specifications 4 System Specifications Meter Specifications Result Range: 20-600 mg/dL Sample Size: Minimum 0.5 microliter (0.5 µL) Sample Type: Fresh capillary whole blood, venous whole blood collected in sodium heparin blood collection tubes only, …HP Printer Driver Support for Linux OS. Linux operating systems are developed and supported by the open source community. To find driver support for the Linux operating system, HP recommends the HP Linux Imaging and Printing website HP Linux Imaging and Printing . Note: The HP Linux Imaging and Printing website is not hosted by HP …TRUE METRIX® AIR Self Monitoring Blood Glucose System TRUE METRIX AIR is a simple, accurate way to test your whole blood glucose (sugar) level, anytime, anywhere. Our goal is to provide quality healthcare products and dedicated customer service. For questions about TRUE METRIX products, visit our web site at: www.trividiahealth.com.Feb 19, 2023 · What Does E-0 Mean on a True Metrix? E-0 means invalid hematocrit. The message indicates the error in the red portion of the blood. You can face this issue for multiple reasons. While testing your diabetes on a true metrix it’s not usual to face this issue. But if you do, then you have to first identify the reason. True Metrix Pro - Home - Trividia Health Frequently bought together. This item: TRUE METRIX® Meter Starter Kit. $3999. +. TRUE METRIX Blood Glucose Test Strips NFRS 100ct (100 Test Strips) $3000 ($0.30/Count) +. 3 x 100ct 30g TRUEplus® Lancets + TRUEplus® Log Book.True Metrix Pro - Home - Trividia Health View and Download True METRIX AIR owner's booklet online. SELF MONITORING BLOOD GLUCOSE SYSTEM. METRIX AIR blood glucose meter pdf manual download.I’ve only just bought my meter, but how could I have an E-2 error? Because it thinks that the strip is expired, but it’s not, because our strips are all super fresh. So what is actually wrong is the date is set incorrectly in the meter.True Metrix Pro - Home - Trividia HealthApr 8, 2018 · I've downloaded pdf's of almost everything we own, from glucose meters to the washing machine I have True Metrix meter, only gotten E-0 code once. Not enough blood. I always lift my arm, and hold for minute then use lancet, don't squeeze finger.Get accurate readings which I download into docking station automatic. Page 45 For Consumers 99.0% of user TRUEyou fingertip values fell within 0.83 mmol/L of the YSI results at glucose levels < 5.55 mmol/L and within 15% at glucose levels > 5.55 mmol/L. Fingertip Samples (user vs. YSI) for glucose concentrations <5.55 mmol/L Within + …This post will assist you to find out what the message means.E-0 is an error code which means invalid hematocrit. There are 8 types of error on a true metrix meter. From e-0 to …New Member. Mar 11, 2017. #1. Hi all! I bought a Freestyle lite meter yesterday. After a few attempts, I got it to work once. Since then I tried 3 times and failed. You are supposed to see 3 lines when it reads the blood sample, but I didn't get even one. I set the lancet to the maximum setting (5) and following advice I read on the forum, I ...Lance fingertip or forearm. Allow drop to form (see Obtaining a Blood Sample). 6. With test strip still in meter, touch Sample Tip of test strip to top of blood drop and allow blood to be drawn into test strip. Remove test strip from blood drop immediately after the meter beeps and dashes appear across the Display. Jul 25, 2022 · True Treadmill Errors and Service Messages The True 600, 700, 725, and 750 series treadmills are equipped with built-in diagnostics and... Walgreens Premium True Metrix Self-Monitoring Blood Glucose Meter Black | Walgreens. 20% off sitewide with code FRIENDS20. Clip your mystery deal! Extra 10% off wellness with code NEW10. Menu.Use with True Metrix Self Monitoring Blood Glucose Test Strips. • Proven accuracy • Features Triple Sense Technology • On-the-go, fully featured. Instructions. For in vitro diagnostic use only. Store at temperature range of 40 - 86 degrees F (4 - 30 degrees C). Do not freeze. More information. Company. Find a Store; About Us;Page 14: Step 2 - Testing Blood Glucose. 3. Place the lancing device against the puncture Step 2 - Testing Blood Glucose Step 2 - Testing Blood Glucose site. Press and hold the clear cap against the puncture site for a few seconds. Press the release button of the lancing device, but Note: Insertion of a new test strip at any time, except while ...2) Open Chrome DevTools and navigate to the Network Tab. With the incognito window open, press F12 on your keyboard, or Ctrl + Shift + I ( Command + Option + I on a Mac) to open up Chrome DevTools. A new window will open up – click on the Network tab in the top menu.If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t.Oct 3, 2023 · Solution. • This means not enough blood. or sample not detected. • Re-test to make sure there. is enough blood and that. you're filling the test strip. properly. • Bring the tip of the strip ... An E3 Error Code means the meter is sensing that blood has already been applied to. the test strip (or the strip has already been used). What to do: Please make …You might be interested. How to Measure Countertop Square Footage for Estimations; How to Cover Tile Countertops with Thin Quartz; DIY Kitchen Remodeling on a Budget: 5 Money-Saving StepsThe True Metrix meter also has features such as a ketone reminder, control detection, and audible fill detection to keep users on track. Strip Release Button Handling a strip after testing can have an impact on its accuracy. The True Metrix blood glucose meter has a handy strip release button.Shop True Metrix Go Self-Monitoring Blood Glucose Meter and read reviews at Walgreens. Pickup & Same Day Delivery available on most store items.For the most accurate results using TRUE METRIX: • Read all product instructions for use before testing. • Use of TRUE METRIX in a manner not specified in this Owner’s Booklet is not recommended and may affect ability to determine true blood glucose levels. Page 6 Control Solution are available for Control Tests.McKesson TRUE METRIX® Self Monitoring Blood Glucose Monitoring System For use with #06-R3051-41 and #06-R3051-45 McKesson TRUE METRIX® Strips, and #06-R5051-1, #06-R5051-2 and #06-R5051-3 McKesson TRUE METRIX® Controls. No coding. As fast as 4 seconds. Tiny 0.5 microliter sample size. Alternate site testing. Store 500 results with …HP Printer Driver Support for Linux OS. Linux operating systems are developed and supported by the open source community. To find driver support for the Linux operating system, HP recommends the HP Linux Imaging and Printing website HP Linux Imaging and Printing . Note: The HP Linux Imaging and Printing website is not hosted by HP …Blood Glucose Control Solution McKesson Quintet AC® 2 X 4 mL Level 1 & 2. #960301. 2,000. McKesson Brand #06-R5051-2. Blood Glucose Control Solution McKesson TRUE METRIX® 3 mL Level 2. #711309. 1,992. Arkray USA #500006. Blood Glucose Control Solution Assure® Dose 2 X 2.5 mL Level 1 & 2.E-5 message is a safety feature to alert customers that there may potentially be issues with the test strip or the blood glucose result being detected by the meter is higher than 600mg/dL.Lance fingertip or forearm. Allow drop to form (see Obtaining a Blood Sample). 6. With test strip still in meter, touch Sample Tip of test strip to top of blood drop and allow blood to be drawn into test strip. Remove test strip from blood drop immediately after the meter beeps and dashes appear across the Display. This website makes use of licensed stock photography. All photography is for illustrative purposes only and all persons depicted are models. This website contains information on products which are targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country.Release the circular button. Meter will go into Set Up mode. The hour flashes. To change, press the left/right arrows located on top of the meter to select the correct hour. Like many alarm clocks, to set AM or PM, scroll through the hours until AM or PM appears in the Display. Press the circular button to set.Blood glucose test result is above 600 mg/dL; blood ketone test result is above 8.0 mmol/L. Wash and dry your hands or test site and repeat the test using a new test strip. If your result still flashes HI, contact your health coach immediately.The information brought to you by Ascensia Diabetes Care US, Inc provides general information. It is not intended to be used as medical advice, diagnosis or treatment and should not replace the advice of your Healthcare Provider.McKesson TRUE METRIX® Self Monitoring Blood Glucose Monitoring System For use with #06-R3051-41 and #06-R3051-45 McKesson TRUE METRIX® Strips, and #06-R5051-1, #06-R5051-2 and #06-R5051-3 McKesson TRUE METRIX® Controls. No coding. As fast as 4 seconds. Tiny 0.5 microliter sample size. Alternate site testing. Store 500 results with …“E-2” in the display means the code key is incorrect. Turn the meter off and make sure the code key is properly inserted. If this does not fix the problem, please contact Accu-Chek Customer Care.If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t.The Walgreens True Metrix Go is a clever, highly compact meter that actually snaps onto the top of a test strip vial, so you have everything you need all-in-one. Like its partner model, the True Metrix Go meter uses a 0.5-microliter sample to deliver blood glucose readings within 4 seconds. It also offers a 500-test memory, 7-, 14-, and 30-day ...I have True Metrix meter, only gotten E-0 code once. Not enough blood. I always lift my arm, and hold for minute then use lancet, don't squeeze finger.Get …The information brought to you by Ascensia Diabetes Care US, Inc provides general information. It is not intended to be used as medical advice, diagnosis or treatment and should not replace the advice of your Healthcare Provider.If the problem persists, please contact GlucoRx Customer Care on 01483 755133 for help. E-t. LOW. Appears when ambient temperature is below system operation range. System operation range is 10°C to 40°C (50°F to 104°F). Repeat the test after the meter and test strip are in the above temperature range. E-t.E-3. Your blood glucose may be too low to be read by the system, or there may be a problem with the test strip. Monitor your blood glucose again with a new test strip. If “E-3” shows again, contact your health coach immediately.Covered by most insurance plans. They are reputed to report their findings consistently, making it possible to understand the potential error margin and to adjust readings. …Mar 7, 2023 · What does e2 mean on true metrix, My mother-in-law had a walgreens meter and it did that giving an e code even though it appeared to boot up when you put a strip in it. Changing the batteries fixed it. Professional Monitoring Blood Glucose System (using TRUE METRIX™ PRO Test Strips with GDH-FAD Enzyme) Comprehensive Resource Guide for Healthcare Professionals (Policies, Processes, and Procedures) Information in this guide is specific For assistance please call: for healthcare professionals using the Customer Care 1-800-803-6025 TRUE METRIX ... Nov 15, 2020 · E-U: Appears when a used test strip is inserted. E-t: Appears when ambient temperature is above or below system operation range. E-0, E-A, E-E: Problem with the meter. E-F: Appears when test strip is removed while counting down, or insufficient blood volume. E-3. Your blood glucose may be too low to be read by the system, or there may be a problem with the test strip. Monitor your blood glucose again with a new test strip. If “E-3” shows again, contact your health coach immediately.TRUE METRIX Self Monitoring Blood Glucose Meter - YouTube There are many different ones available in the market although True Metric has been one of the greatest popularity ones recent. The software helps you with an advanced package systematisches that is useful to build lifestyle decisions basic on what lift your lactose …This website makes use of licensed stock photography. All photography is for illustrative purposes only and all persons depicted are models. This website contains information on products which are targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country.How to use Level 1, Level 2 and Level 3 control solution with the True Metrix Blood sugar meters.Buy control solution at Diabetic Warehouse https://bit.ly/39...Summary of Contents for Trividia TRUE METRIX AIR. Page 2 1. FDA Public Health Notification: Use of Fingerstick Devices on More than Guarde el TRUE METRIX AIR sistema en un lugar seco a temperaturas entre 4.44 °C y 30 °C (40 °F y One Person Poses Risk for Transmitting Blood Borne Pathogens. Obtenido One Person Poses Risk for Transmitting ... Apr 25, 2020 · En este caso queremos que conozcas los errores más comunes que presentan los glucómetros, un dispositivo que ha sido pionero e indispensable en el tratamiento de la diabetes, pero que en algún momento pueden fallar y por eso es importante saber qué significa cada falla. Errores comunes en los glucómetros Defines aggregating of multiple output values. Array-like value defines weights used to average errors. ‘raw_values’ : Returns a full set of errors in case of multioutput input. ‘uniform_average’ : Errors of all outputs are averaged with uniform weight. squared bool, default=True. If True returns MSE value, if False returns RMSE value.This bundle contains 2 items. TRUE Metrix® AIR Starter Kit Plus TRUE METRIX® Blood Glucose Test Strips NFRS 100ct - 2 Pack (200 Test Strips) TRUE Metrix® AIR Starter Kit Plus TRUE METRIX® Blood Glu…. $102.49. $102.• For use only with McKesson TRUE METRIX ® and TRUE METRIX ® PRO Blood Glucose Test Strips • Not intended for human consumption • For in vitro diagnostic use only Store at temperature range of 36-86°F (2-30°C). DO NOT FREEZE. Distributed By McKesson Medical-Surgical Inc. Richmond, VA 23228 Rev. 00 03/15 Made in USA R5SUN01 rev 1E-5 message is a safety feature to alert customers that there may potentially be issues with the test strip or the blood glucose result being detected by the meter is higher than 600mg/dL. Oct 3, 2023 · Solution. • This means not enough blood. or sample not detected. • Re-test to make sure there. is enough blood and that. you're filling the test strip. properly. • Bring the tip of the strip ... TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) System Specifications 4 System Specifications Meter Specifications Result Range: …Performance problems include falsely high or low results or incorrect calibration. These errors could be related to the meter or the test strips. The meter company will be able to help discover which. Some blood glucose meters require a calibration code to be entered which can lead to mistakes and errors.E, 0, 9 **MP270 only** The machine has not received a response from the digital camera. The digital camera or digital video camcorder connected is not compatible with this machine.Use with True Metrix Self Monitoring Blood Glucose Test Strips. • Proven accuracy • Features Triple Sense Technology • On-the-go, fully featured. Instructions. For in vitro diagnostic use only. Store at temperature range of 40 - 86 degrees F (4 - 30 degrees C). Do not freeze. More information. Company. Find a Store; About Us;With the TRUE MANAGER™ AIR Mobile App, TRUE METRIX® AIR Blood Glucose Meter with Bluetooth Smart technology, and certain mobile devices, you can track data to get valuable insights that link daily activity with your glucose results from the meter’s memory. Easy-to-read charts, graphs and customizable notes make understanding data …E-3 message is a safety feature to alert you that the test strip may be used, or the test strip may have been left outside of vial too long or the test sample may have been applied on top of the test strip. Meter basics. The Walgreens True Metrix also uses a 0.5-microliter sample to deliver blood glucose readings within 4 seconds. This meter offers a 500-test memory, alternate site testing, 7-, 14-, and 30-day averages, event tagging, and the ability to download your data to a computer. User reviews.TRUE METRIX® Blood Glucose Monitoring System Troubleshooting Steps Meter Does not Turn on with Strip Meter is dead or does not power on with a strip insertion or by pressing the power button. Battery symbol appears and beeps before meter turns off. Dead meter or meter does not turn on can be caused by: • A dead battery. Meter basics. The Walgreens True Metrix also uses a 0.5-microliter sample to deliver blood glucose readings within 4 seconds. This meter offers a 500-test memory, alternate site testing, 7-, 14-, and 30-day averages, event tagging, and the ability to download your data to a computer. User reviews.this is about the pharmacy give my mom since vor testing, after she is with medicare.she has been having a frightful time with it. More than 50% of the time...The Walgreens True Metrix also uses a 0.5-microliter sample to deliver blood glucose readings within 4 seconds. This meter offers a 500-test memory, alternate site testing, 7-, 14-, and 30-day averages, event tagging, and the …TRUE METRIX® AIR Self Monitoring Blood Glucose System TRUE METRIX AIR is a simple, accurate way to test your whole blood glucose (sugar) level, anytime, anywhere. Our goal is to provide quality healthcare products and dedicated customer service. For questions about TRUE METRIX products, visit our web site at: www.trividiahealth.com. Codes from the Manual:E-1: Temperature is too hot or too cold for the system to work properly. Move your monitor and test strips to a location where the temperature is appropriate and monitor again with a new test strip. You may have to wait for your monitor to adjust to the new temperature. Refer to your test strip instructions for use …Mar 20, 2023 · TRUE METRIX test strips 50 count box. Test strips require only a tiny 0.5 µL (microliter) blood sample. Detects sample environment, sample size, and control solution. Analyzes environmental and physiological factors. Corrects hematocrit/temperature. For use with TRUE METRIX meters. Training Certification Program. Our TRUE METRIX ® PRO System is designed to function accurately and reliably for years with proper care and operation. Extensive education, training, and support for you and your patients. Learn more about how to get certified in the correct use and handling of the TRUE METRIX ® PRO Professional Monitoring ...This bundle contains 2 items. TRUE Metrix® AIR Starter Kit Plus TRUE METRIX® Blood Glucose Test Strips NFRS 100ct - 2 Pack (200 Test Strips) TRUE Metrix® AIR Starter Kit Plus TRUE METRIX® Blood Glu…. $102.49. $102.Perform Control Tests before performing a blood glucose test for the first time. Perform Control Tests with more than one level of control solution. Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025, Monday - Friday, 8AM-8PM EST, for assistance in obtaining diferent levels of control solution.In rare cases, an E-3 message may indicate that your blood glucose is extremely high and above the system’s measuring range. In addition, the message could appear if the cap on the test strip container was not closed tightly. Use with True Metrix Self Monitoring Blood Glucose Test Strips. • Proven accuracy • Features Triple Sense Technology • On-the-go, fully featured. Instructions. For in vitro diagnostic use only. Store at temperature range of 40 - 86 degrees F (4 - 30 degrees C). Do not freeze. More information. Company. Find a Store; About Us;Oct 3, 2023 · Solution. • This means not enough blood. or sample not detected. • Re-test to make sure there. is enough blood and that. you're filling the test strip. properly. • Bring the tip of the strip ... this is about the pharmacy give my mom since vor testing, after she is with medicare.she has been having a frightful time with it. More than 50% of the time...Blood glucose test result is above 600 mg/dL; blood ketone test result is above 8.0 mmol/L. Wash and dry your hands or test site and repeat the test using a new test strip. If your result still flashes HI, contact your health coach immediately.

Perform Control Tests with more than one level of control solution. Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025, available 24 hours a day, 7 days a week, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY.. What is how to become

true metrix error codes e 0

True Metrix Error Codes for True Metrix Air and Go blood glucose meters. Potential error codes that may occur while testing blood sugar. Specific Error Codes …3) Try to Reset or Repair the game in Windows Settings > Apps > Apps & Features > [Name of game] > Advanced Options > Reset or Repair. Restart PC. 4) If that's not enough then uninstall the game from the same place, restart PC, reinstall the game from MS Store Hub (three dots at top right of Store app) > My Library.Apr 25, 2020 · En este caso queremos que conozcas los errores más comunes que presentan los glucómetros, un dispositivo que ha sido pionero e indispensable en el tratamiento de la diabetes, pero que en algún momento pueden fallar y por eso es importante saber qué significa cada falla. Errores comunes en los glucómetros The TRUE METRIX Self-Monitoring Blood Glucose System is intended for self-testing outside the body (in vitro diagnostic use). To assure you are getting accurate and reliable results, you can perform a Control Test (Refer to Owner’s Booklet). 15197:2015(E). Brussels: European Committee for Standardization; 2015. 2 SYSTEM SPECIFICATIONS. IMPORTANT HEALTH and SAFETY INFORMATION • Use of the TRUE METRIX GO System in a manner not specified in this System Instructions for Use is not recommended and may affect the ability to determine true blood glucose levels.Add a tiny drop of blood, and the meter will show your blood sugar (blood glucose) level on a display screen. How often you check depends on a number of factors, including your diabetes type and whether you're taking insulin, so talk to your health care provider for guidance. Other meters may be available that are not listed here.Perform Control Tests with more than one level of control solution. Three levels of TRUE METRIX Control Solution are available for Control Tests. Call 1-800-803-6025, available 24 hours a day, 7 days a week, for assistance in obtaining control solution. The TRUE METRIX AIR Self Monitoring Blood Glucose System is for one person use ONLY.The information brought to you by Ascensia Diabetes Care US, Inc provides general information. It is not intended to be used as medical advice, diagnosis or treatment and should not replace the advice of your Healthcare Provider.This website makes use of licensed stock photography. All photography is for illustrative purposes only and all persons depicted are models. This website contains information on products which are targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country.TRUE METRIX™ PRO System Comprehensive Resource Guide (GDH-FAD Enzyme) Intended Use Statement 2 Intended Use Statement The TRUE METRIX™ PRO Blood Glucose Monitoring System is intended for the quantitative determination of glucose in human whole blood taken from the fingertip or forearm (capillary) or from the vein (venous). The system is ... This bundle contains 2 items. TRUE Metrix® AIR Starter Kit Plus TRUE METRIX® Blood Glucose Test Strips NFRS 100ct - 2 Pack (200 Test Strips) TRUE Metrix® AIR Starter Kit Plus TRUE METRIX® Blood Glu…. $102.49. $102.Oct 3, 2023 · Solution. • This means not enough blood. or sample not detected. • Re-test to make sure there. is enough blood and that. you're filling the test strip. properly. • Bring the tip of the strip ... Page 14: Step 2 - Testing Blood Glucose. 3. Place the lancing device against the puncture Step 2 - Testing Blood Glucose Step 2 - Testing Blood Glucose site. Press and hold the clear cap against the puncture site for a few seconds. Press the release button of the lancing device, but Note: Insertion of a new test strip at any time, except while ...Was released from the vet last night and this morning all I am getting on the blood meter reading is E-5. I tested on me and got a normal numerical reading. I fed her and gave 2 units of Lantus at 8am and retested there blood at 11 and still got E-5. using the Trueresult metering system. My vet opens at 3pm which seems a long time away..

Popular Topics